Particle size distribution (PSD) shows how much of a powder or slurry falls into each size range, drawn as a curve. A narrow PSD means uniform particles; a broad or bimodal PSD means mixed sizes. PSD controls flow, packing, strength, colour and dissolution in minerals, cement, paints and fertilizers.

Two powders can have the same average particle size and still behave very differently in a plant. One flows smoothly through the hopper while the other bridges and blocks. One gives a smooth, glossy paint film while the other leaves a rough surface. In most cases, the difference comes from the particle size distribution, not the average size.

That is why manufacturers, buyers and quality teams depend on PSA testing to understand their materials. At SGM National Laboratory in Udaipur, we carry out particle analysis on calcite, dolomite, quartz, feldspar, talc, cement, fly ash, fertilizers and pigments for industries across India. In this guide, we explain what a particle size distribution curve shows, how to read it, what different curve shapes mean, and how processing changes the result, using three PSD curves from our own laboratory reports.

How to Read a Particle Size Distribution Curve

A particle size distribution curve plots particle size on the X-axis, usually in microns (µm) on a logarithmic scale, against the amount of material on the Y-axis. A typical PSA laboratory report presents this data in two ways.

  • Frequency curve: A hump or bell-shaped graph. The highest point shows the most common particle size in the sample.
  • Cumulative curve: An S-shaped line that rises from 0% to 100%. At any size, it shows what percentage of the sample is finer than that size.

D10, D50 and D90 – The Key Values

Most PSD reports summarise the cumulative curve with three values:

  • D10: 10% of the sample is finer than this size. It describes the fine fraction.
  • D50 (median): Half the sample is finer and half is coarser. It represents the typical particle size.
  • D90: 90% of the sample is finer than this size. It describes the coarse end, also called the top cut.

Span – Measuring the Width

Span tells you how wide the particle size distribution is:

Span = (D90 − D10) ÷ D50

A low span means a tight, uniform powder. A high span means a wide mix of sizes. Comparing D-values and span between batches is one of the fastest ways to spot process changes through routine PSA analysis.

What Is a Narrow vs Broad Particle Size Distribution?

The width of a curve is just as important as the position of its peak. Two powders with the same D50 can have very different widths.

Narrow PSD

A narrow particle size distribution has a tall, thin peak and a steep S-curve. Most particles are close to the same size, and D10 and D90 sit near each other.

A narrow PSD is preferred where consistent behaviour is required:

  • Paints and coatings: Uniform filler particles give an even film, stable gloss and consistent viscosity.
  • Filtration media and abrasives: Particle size directly controls performance.
  • Chemical and dissolution processes: Similar-sized particles react or dissolve at a steady, predictable rate.

The trade-off is packing. Same-sized particles leave empty spaces between them, which lowers bulk density.

Broad PSD

A broad particle size distribution has a wide, low hump and a gentle S-curve. The sample contains coarse, medium and fine particles together.

This can be an advantage. Fine particles fill the gaps between coarse particles, so the material packs more densely. That is why cement, ceramic bodies, refractories and concrete mixes are designed with a controlled broad PSD to improve strength and reduce porosity.

The risks include segregation during transport and storage, higher dust levels and less predictable flow. Regular PSA testing on incoming raw materials and finished batches helps catch these issues before they affect production.

What Does a Bimodal PSD Curve Mean?

A bimodal PSD curve has two separate peaks instead of one. It shows that the sample contains two distinct groups of particles, one finer and one coarser.

Intentional Bimodal Distributions

Sometimes a bimodal particle size distribution is created on purpose. Manufacturers blend two grades so the fine particles fill the spaces between the coarse ones. This improves packing density in ceramics, highly filled polymer compounds and certain construction products.

Unintentional Bimodal Distributions

More often, a second peak signals a problem that needs attention:

  • Agglomeration: Fine particles stick together and appear as a false coarse peak.
  • Incomplete grinding: Part of the feed passed through the mill without proper size reduction.
  • Mixing or contamination: Two different materials or batches have been combined.
  • Poor dispersion during testing: Particles were not fully separated before measurement.

An experienced PSA laboratory confirms a second peak before reporting it. At SGM, we repeat the measurement with different dispersion energy, such as longer ultrasonication or higher air pressure. If the coarse peak reduces, it was caused by agglomerates rather than true coarse particles. This step prevents wrong conclusions and unnecessary process changes.

Volume vs Number Distribution – Which Should I Use?

The same powder can produce very different results depending on how particles are counted. This is one of the most common sources of confusion in particle analysis.

A particle 10 µm wide has about 1,000 times the volume of a particle 1 µm wide. Because of this:

  • A number distribution counts every particle equally. Fine particles dominate it because they are present in very large numbers.
  • A volume distribution weights each particle by its volume or mass. Coarse particles dominate it because they hold most of the material.

Laser diffraction, the most widely used PSA testing method, reports a volume-based particle size distribution by default.

When to Use Volume Distribution

Volume or mass-based data suits most industrial applications, including mineral fillers, cement, fly ash, slurries, fertilizers and pigments. It shows where the bulk of your material lies, which is what controls strength, flow, coverage and yield.

When to Use Number Distribution

Number-based data is useful when the count of individual particles matters. Examples include monitoring ultrafine particles in pharmaceuticals, counting contaminant particles and studying nanomaterials. Image analysis methods give number data directly.

Converting between the two bases assumes that particles are spherical, so small errors can grow large. Always check which basis a report uses before comparing two PSD results, and keep the same basis across suppliers and production batches.

How Does Grinding Change PSD?

Grinding does more than reduce the average particle size. It changes the entire shape of the particle size distribution curve.

The Curve Shifts Toward Finer Sizes

As grinding time or mill energy increases, D50 decreases and the whole curve moves to the left. This is the intended result of size reduction.

The Fine Tail Grows

Particles do not break evenly. Longer grinding produces more ultrafine material, which stretches the fine side of the curve and increases the span. Over-grinding also wastes energy and can make powders dusty and difficult to handle.

Agglomeration Can Create a False Coarse Peak

Very fine particles tend to stick together. Beyond a certain point, extra grinding can produce a coarse shoulder or even a bimodal PSD, although the true particle size is still decreasing.

Classifiers Narrow the Distribution

Closed-circuit grinding with an air classifier returns oversize particles to the mill. This controls D90 and produces a narrower particle size distribution, which is why classified mineral powders usually show a lower span.

Running PSA analysis at regular grinding intervals shows exactly when the target D50 and D90 are reached and when further grinding stops adding value.

Three Real PSD Curves from SGM Reports

The following curves are taken from SGM National Laboratory test reports. Client and sample details have been kept confidential.

Curve 1 – Narrow PSD (Classified Mineral Filler)

This sample shows a single tall peak and a steep cumulative curve. D10, D50 and D90 lie close together, giving a low span. This pattern is typical of air-classified filler grades produced for paints, coatings and plastics, where uniform particle size supports consistent quality.

Curve 2 – Broad PSD (Ground Raw Material)

Here the peak is wide and flat, and the cumulative curve rises gradually across a wide size range. The high span confirms a mixture of coarse and fine particles. This is common in mill output without classification and in materials designed for dense packing.

Curve 3 – Bimodal PSD (Two Particle Populations)

This curve shows two clear peaks, indicating two particle populations in the same sample. Our team re-tested it with higher dispersion energy to check whether the second peak came from agglomerates or from genuinely coarse material. This example shows why a single D50 value is never enough. Only the full curve reveals what is really inside a sample.

All three samples were tested by laser diffraction, using wet or dry dispersion selected for each material. Coarser materials are also checked with sieve analysis when required

Conclusion

Particle size distribution is one of the most valuable quality checks for any powder or slurry. D50 tells you the typical size, but the full PSD curve reveals the complete picture. A narrow curve supports uniform performance, a broad curve helps achieve dense packing, and a bimodal curve may point to blending, agglomeration or a process issue. If you know whether your report is volume-based or number-based, and how grinding shifts the curve, you can compare batches accurately and control your process with confidence.

For accurate PSA testing of minerals, cement, fly ash, fertilizers and pigments, SGM National Laboratory provides detailed reports with full curves, D-values and expert interpretation. Explore our particle size analysis services and send your samples to a trusted PSA laboratory in India.

FAQS

It describes how the particles in a powder, slurry or emulsion are spread across different size ranges, shown as a curve or table instead of one average number.

PSD means particle size distribution. The short form is common in lab reports, product specifications and supplier certificates.

A narrow PSD means most particles are close to the same size. A broad PSD covers a wide spread of sizes, which can improve packing but changes flow and finish.

A curve with two peaks, showing two main size groups in the sample. It often points to blending of two materials, agglomerates or incomplete grinding.

Laser diffraction usually reports by volume, while image analysis often reports by number. The same sample can look different on each basis, so check which one is used.

Minerals, cement, ceramics, paints, pigments, fertilizers, plastics, pharmaceuticals and food all use PSD to control quality and performance.

Send a representative sample with the material name and expected size range to SGM National Laboratory. The report includes the curve plus D10, D50 and D90.

PSA testing (particle size analysis) measures the size range of particles in a powder or slurry. It reports D10, D50, D90 and the full PSD curve, which helps industries control the flow, packing, strength and quality of minerals, cement and fertilizers.

 

PSA analysis is mainly done by laser diffraction for fine powders, sieve analysis for coarse materials and image analysis for shape and number data. The right method depends on particle size range, material type and the standard your buyer requires.

 

Choose a PSA laboratory with calibrated laser diffraction equipment, proven dispersion methods, experience with your material and clear reports with full curves and D-values. SGM National Laboratory in Udaipur offers this for Indian industries.

Leave a Reply

Your email address will not be published. Required fields are marked *